All fuses and breakers in the system are listed below:
30A Main Breaker Panel
- In – Furrion 30A Inlet
- Out – Multiplus AC IN
30A Main + 6 Breaker Panel
- In – Multiplus AC OUT-1
- Breaker 1, 15A: top-right outlet
- Breaker 2, 15A: bottom-right outlet
- Breaker 3, 15A: top-left outlet
- Breaker 4, 20A: (“Appliances”): bottom-left outlet
- Breaker 5 & 6: Unused
Class T Fuse
- 300A, Battery Bank Catastrophic Fuse
Mega Fuses – Lynx Distributer
- Position 1, 80A: 24/12 Converter
- Position 2, 80A: Smart Battery Protect (SBP)
- Position 3, 250A: Multiplus
- Position 4: 100A: Orion XS 1400s, Solar
Single Mega Fuse Holder
- 80A: Output of 24/12 Converter to 12V Fuse Panel
150A Breaker Under Truck Hood
- In – Driver-side positive battery terminal
- Out -Solenoid input
Inline Fuse Holder Under Truck Hood
- Solenoid coil, under truck hood driver side back wall, 5A
Dual MRBF Fuse Holder attached to 3/8″ feed-through connector from solenoid output
- 75A (left): Input to left Orion XS 1400
- 75A (right): Input to right Orion XS 1400
3-Circuit MRBF Common Fuse Block below Right Orion XS 1400 (number from left)
- Position 1, 40A, Output from MPPT 150 | 35
- Position 2, 75A: Output from left Orion XS 1400
- Position 3, 75A: Output from right Orion XS 1400
12V Fuse Panel: Top Row (numbered from left)
- Position 1, 15A: 12V outlet, left side of cabinet
- Position 2, 20A: Nilite 3-gang switch panel, right side of cabinet
- Position 3, 15A: 12V outlet, right side of cabinet
- Position 4, 3A: thermostat-controlled fan
12V Fuse Panel: Bottom Row (numbered from left)
- Position 1, 10A: rear flood lights
- Position 2, 10A: lights/fan
- Position 3, 30A: water system
SBP Powered 24V Fuse Panel (Right of SBP, numbered from bottom)
- Position 1, 10A: Fridge
- Position 2, 5A: 5.5×2.1mm female outlet, used for Starlink Mini, left side of cabinet
- Position 3, 30A: Anderson Powerpole outlet, used for diesel heater, left side of cabinet
Cerbo GX Powered 24V Fuse Panel (Left of Cerbo)
- Position 1 (top), 1A: Lynx BMS main terminal block, position 5, ATD pin
- Position 4 (bottom), 1A: Cerbo GX positive power pin
Miscellaneous Inline Cabinet Fuses
- Red LED light strip, lower-right corner of cabinet, 5A
Water System Inline Fuses
- Nilite 2-gang switch panel power, near positive bus bar in the rear, 20A
- Switch #1 (from the left), water pump, fuse attached to switch, 15A
- Switch #2 (from the left), tank lights, fuse attached to switch, 7.5A